Gas Cylinder Testing & Recertification

Periodic inspection and hydrostatic testing to ISO 18119 and EU Pi-mark (TPED) standard, carried out at our Kilmallock facility, with certification paperwork you can hand straight to your customer.

ISO 18119 TPED compliant ADR road transport Fire suppression

What periodic inspection involves

Every cylinder that comes through our doors goes through the same disciplined process, regardless of what it held or who it belongs to.

  • External examination — checking the cylinder shell for corrosion, dents, gouges, fire damage and any deformation that would affect safe use.
  • Internal examination — inspecting the internal surface for corrosion, pitting or contamination once the valve is removed.
  • Hydrostatic test — pressurising the cylinder with water to a set test pressure to confirm it holds pressure safely and hasn't stretched beyond an acceptable limit.
  • Valve inspection — checking the valve and any pressure-relief device, servicing or replacing where required.
  • Stamping & certification — cylinders that pass are stamped with the test date and our identification mark, and issued with certification paperwork for your records.
Pressure gauges and regulators on gas cylinders in a test bay

Cylinder types we handle

If it's a refillable gas cylinder, chances are we can test it.

Fire extinguisher & CO2 cylinders

Including CO2 overhaul work for extinguisher servicing companies. See our fire protection page.

Industrial & welding gas cylinders

Oxygen, acetylene, argon, nitrogen and mixed-gas cylinders for gas and welding suppliers.

Beer gas & CO2 cylinders

Dispense cylinders for breweries, pubs and beverage suppliers. See our brewing & beverage page.

Dive & SCBA cylinders

Scuba cylinders and breathing-air cylinders for dive centres and fire services.

LPG cylinders

Propane and LPG cylinders for domestic and commercial use.

Fire suppression system cylinders

FM-200, Novec 1230, inert gas (IG-541, IG-55, IG-100) and CO2 total-flooding system cylinders tested, refilled and decommissioned — the only facility in Ireland equipped to handle them. See fire suppression.

Not sure?

Call us on (063) 69 698 or send details through our quote form and we'll confirm whether we can test it.

Close-up of a gas cylinder valve and regulator

Paperwork you can trust

Every cylinder that passes inspection is stamped with the test date and issued with certification confirming it has been tested to EU Pi-mark standard. That paperwork travels with the cylinder — useful for your own compliance records and for reassuring your customers.

Cylinders that fail are held separately and reported back to you, with an explanation of why, rather than being quietly returned untested.

Not sure whether your cylinders tested elsewhere are still valid for use in Ireland? Read our guide: Why Test in Ireland.

The standards we test to

Compliance isn't a footnote for us — it's the reason customers choose to test in Ireland rather than ship to the UK.

ISO 18119

The international standard for periodic inspection and testing of seamless steel and seamless aluminium alloy gas cylinders and tubes. Every cylinder is examined, tested and marked in accordance with it.

TPED & Pi-mark

Periodic inspection under the EU Transportable Pressure Equipment Directive (2010/35/EU), so cylinders leave with valid Pi-mark status for use and transport across Ireland and the EU.

ADR

Fully compliant for the carriage of dangerous goods by road. Cylinders are collected, transported and returned legally — no grey areas for your own transport compliance.

Ready to book a collection?

Tell us what you have and we'll come back with pricing, turnaround and collection options.

Call (063) 69 698 Get a quote